This wheel-mounted LPG infrared gas heater is a practical, energy-saving heating solution for homes, offices, shops, garages and semi-ventilated indoor spaces. Equipped with high-efficiency ceramic infrared burner, it delivers instant, gentle radiant heat with low gas consumption. Built with complete multi-layer safety protection including flame failure cut-off, anti-tilt and overheat safety locks, it fully meets international gas appliance safety standards. Designed with silent rolling casters and a side carry handle for flexible movement between rooms, the compact vertical body saves floor space, making it ideal for supplementary winter heating in offices, apartments and small commercial spaces.
High-Efficiency Infrared Ceramic Heating
Adopts advanced infrared ceramic burner, fast heat output, uniform radiant warmth without dry air, greatly reduces gas consumption compared to traditional heating devices.
3 Adjustable Heating Mode
Low / Medium / High heat power settings to freely adjust temperature according to room size and ambient coldness, flexible for different heating demands.
Full Set of Multi-Safety Protection System
Flame Failure Device (FFD): Automatically cuts off gas supply once the flame extinguishes accidentally to prevent dangerous gas leakage.
Anti-Tilt Protection: Instantly shuts gas output if the heater tips or falls over.
Overheat Protection: Cuts gas input automatically when internal temperature exceeds the safe threshold.
Front high-density metal safety grille blocks direct contact with hot burner surface to avoid scald injuries for kids and pets.
Mobile & Space-Saving Design
4 lockable silent rolling casters for easy sliding; integrated side carry handle for convenient transport. Slim vertical body takes minimal floor space, perfect for office cubicles, narrow rooms and small apartments.
Durable Thickened Metal Housing
Anti-rust matte metal outer shell, wear-resistant and easy to wipe clean; top double-layer air intake slits guarantee sufficient oxygen supply for complete combustion, lowering carbon monoxide risks.
Wide Fuel Compatibility
Works perfectly with standard LPG, butane and propane gas cylinders, compatible with certified gas pressure regulators and connecting hoses.
Simple Manual Control Knob
Easy one-knob operation for ignition and heat adjustment, with a red safety lock button for secure ignition.
Heating Type: Infrared Radiant Gas Heater
Applicable Fuel: LPG / Butane / Propane
Heat Levels: 3 adjustable power modes
Safety Functions: Flame Failure Cut-off, Anti-tilt Shut-off, Overheat Protection, Safety Mesh Grille
Mobility: 4 lockable rolling casters + side portable handle
Outer Material: Thickened cold-rolled matte metal sheet
Burner: High-efficiency infrared ceramic burner
Installation Type: Freestanding, no wall mounting required
Applicable Area: Small to medium semi-ventilated indoor spaces
Perfect for indoor semi-ventilated environments: office cubicles, family living rooms, small apartments, retail shops, garages, temporary construction offices, farm houses and semi-open balconies. Great for daily winter heating, supplementary space heating and temporary warmth supply.
Place the heater on a flat, solid, non-flammable floor, lock the rolling casters to prevent sliding. Maintain a minimum 1m clearance from walls, curtains, furniture and all combustible materials.
Connect the LPG gas cylinder to the heater’s gas inlet with a certified pressure regulator and gas hose. Tighten all connecting joints firmly.
Gas leak test: Brush diluted soapy water on all gas connections. If bubbles appear, close the gas cylinder valve immediately and re-tighten fittings. Never use open flame to check gas leakage.
Ensure the room has proper natural ventilation for oxygen supply during combustion.
Slowly open the valve of the gas cylinder.
Press and hold the red safety control button fully down, rotate the main adjustment knob to the ignition position. Keep holding the red button for 10–30 seconds to activate the flame failure thermocouple.
After the burner ignites steadily, release the red button, then adjust the knob to Low / Medium / High heat output as needed.
If ignition fails, turn all knobs to OFF, wait 5 minutes to discharge residual gas, then repeat the ignition steps.
Adjust the heat gear to control indoor temperature according to actual heating demand.
Rotate the main control knob to the OFF position to cut off gas supply to the burner.
Fully close the valve of the LPG gas cylinder.
Leave the heater to cool completely before moving, cleaning or storage.
This heater consumes oxygen while working. Forbid use in fully sealed bedrooms, bathrooms, caravans, tents and airtight small rooms, to avoid oxygen depletion and carbon monoxide poisoning.
Do not cover the top air vents, front burner grille or any part of the heater with clothes, blankets, plastic or other flammable items.
The front grille and burner reach extremely high temperatures during operation. Keep children and pets far away to prevent scald burns.
If you smell gas leakage, shut down the gas cylinder valve at once, open all windows for ventilation, do not touch any electrical switches, and contact professional gas maintenance staff immediately.
Do not store spare gas cylinders beside the running heater.
Do not move the heater when it is lit or still hot. Keep casters locked during the whole heating process.
Never use this heater as a clothes dryer or towel warmer.
Do not spray paint, hair spray, insecticide or other flammable aerosols near the working heater.
Equipped with flame failure protection: If the flame is blown out accidentally, the device will automatically cut off gas supply. When this happens, turn off the heater, wait 5 minutes to exhaust residual gas before re-ignition.
Stop using the heater immediately if the gas hose, regulator or metal casing is cracked, aged or damaged.
Only applicable for LPG / Butane / Propane gas. Do not connect to natural gas pipeline without professional modification.
Do not use outdoors on rainy, windy days. Moisture will corrode internal components and cause gas leakage risks.
Always turn off the heater, close the gas cylinder valve, and wait for full cooling before any cleaning work.
Wipe the outer metal shell with a soft dry cloth; slightly damp cloth can be used for stubborn stains (no corrosive detergent).
Clean top air intake slits and front safety grille with a soft brush or low-power vacuum cleaner every month. Blocked vents will cause incomplete combustion and carbon monoxide hazards.